A surge program reports heads and flows; the pipe fails at its supports. When a pressure wave runs along a straight leg between two bends, the pressure at one end differs from the pressure at the other, and the difference acts on the pipe as an unbalanced axial force. On the 12 km DN800 reference main, a line valve closed instantly at the far end loads a 50 m above-ground leg with 733 kN for 48 ms. Close the valve in 5 s and the same leg sees 81 kN. With the series vessel protecting a pump trip, the leg next to the pump sees 17 kN. A support designed for the static thrust at a bend, or only for friction along the pipe, can take none of the first. This article shows how to turn the transient results into forces, how a support's natural frequency changes what it feels, and what to hand to the structural engineer.

1 · Two different forces

Pipe supports see two kinds of hydraulic load [1][2]:

The second is easy to miss, because a surge model draws envelopes along the line rather than differences between two points at the same instant, yet it is the load that shakes above-ground pipework off its supports, opens restrained joints and fails pipe racks in pump stations.

2 · Bend thrust at the surge pressure

For the reference main (DN800, \(A\) = 0.503 m²) a 90° bend carries 591 kN at the steady 85 m, 829 kN at the 119 m peak of the protected trip, and 1,322 kN at the unprotected 190 m. The momentum term is small at these velocities (about 1.4 kN). Thrust blocks and anchors are designed on the maximum pressure of the envelope at that bend, which is why the envelope must be read at every bend and not only at the pump.

Bend thrust against deflection angle
\(F_b = 2A(\rho g h + \rho v^2)\sin(\theta/2)\), \(\rho\) = 998 kg/m³. Lines for the steady pressure head and the transient maximum at the bend.
Internal area from the nominal diameter.
At the bend, from the steady model.
From the envelope at the bend.
Angle between the two legs' directions.
Steady.
Steady thrust
–
Transient thrust
–
Increase
–
Momentum part
–

3 · Unbalanced force on a straight leg

We took the transient heads at the two ends of a straight leg next to the event and formed \(F_L(t)\) for four cases on the reference main: the pump trip without protection, the pump trip with the series vessel, and a line valve at 12 km closing instantly or in 5 s. The model uses 50 m reaches so the leg ends fall on nodes [4].

Unbalanced axial force on a leg next to the event
\(F_L = \rho g A (H_1 - H_2)\) from method-of-characteristics heads at the two ends of the leg, DN800, \(a\) = 1,050 m/s, 50 m reaches. Positive acts towards the event (the pump or the valve). Traces thinned for the page, keeping every peak.
The leg sits at the pump, or at the valve.
Between the two bends.
Zoom on the largest pulse.
Peak force
–
At
–
Pulse length (half height)
–
L/a
–

An instant closure sends the full Joukowsky front (149 m) into the leg: 733 kN whatever the leg length, lasting \(L/a\), from 48 ms on a 50 m leg to 0.19 s on a 200 m leg. A 5 s closure spreads the front over 5 km of pipe, so the head difference across a leg grows with its length: 81, 153 and 273 kN for 50, 100 and 200 m. The unprotected pump trip peaks at 521 kN when cavities near the pump collapse 47 s after the trip, a load no envelope shows. The vessel keeps the leg below 30 kN.

4 · What the support feels: dynamic load factor

A support with a natural period \(T\) does not feel a short pulse as a static load. For a rectangular pulse of duration \(t_d\) applied suddenly, the peak response of a single-degree-of-freedom system, as a multiple of the static response to the same force, is [5][6]

\[ DLF \;=\; 2\sin\!\left(\frac{\pi t_d}{T}\right) \quad \text{for } \frac{t_d}{T} \le \tfrac12, \qquad DLF = 2 \quad \text{otherwise} \]

and for a load that rises over a time \(t_r\) and then stays,

\[ DLF \;=\; 1 + \frac{\left|\sin(\pi t_r/T)\right|}{\pi t_r/T} \]

A suddenly applied load that lasts longer than half the support's period doubles its effect. A pulse much shorter than the period is felt only partly. A load that builds slowly compared with the period is felt as static.

Dynamic load factor for the selected pulse
Rectangular pulse (sudden, lasting \(t_d\)) and ramp (rising over \(t_r\), then held), single degree of freedom, undamped. The marker uses the pulse length of the case selected above and the support frequency chosen here.
From the structural engineer, for the direction of the force.
How the force arrives.
Support period T
–
Pulse / T
–
DLF
–
Equivalent static force
–

A stiff 10 Hz support (T = 0.1 s) under the instant-closure pulse on a 50 m leg (48 ms) has td/T = 0.48 and a DLF of 2.0: the support must be designed for about 1,460 kN. A flexible 2 Hz support sees td/T = 0.1 and a DLF of 0.6, but it moves a long way doing so. For the 5 s closure most of the head rise comes in the last moments of the stroke, so the leg still sees a pulse (0.29 s on a 50 m leg), longer than a stiff support's period: the DLF stays at 2. The slower closure helps by making the force smaller, not the factor.

5 · What to hand to the structural engineer

The cheapest fix is usually upstream: slow the closure (see control valve closure time), protect the trip (see choosing surge protection), or avoid long straight legs between bends next to fast valves. Burying or restraining the pipe moves the load into the soil and the joints, which must then be checked for it. The static design of above-ground pipe is covered in above-ground pipeline design.

6 · Getting the forces out of Bentley HAMMER

HAMMER reports heads, pressures and flows at nodes and along pipes; the force on a leg is a short calculation on two of them [7].

  1. Put nodes at every bend of the above-ground or plant-room pipework, so each straight leg is one pipe between two nodes, and give the short pipes their real lengths (see time step and adjustment: short pipes need care).
  2. Report every time step at those nodes, so the pulse is not thinned out.
  3. Export the head histories of the two end nodes of each leg, and form \(F_L(t) = \rho g A(H_1 - H_2)\) in a spreadsheet; add the bend thrusts from the maximum pressure at each bend.
  4. Check the pulse is resolved: the leg must be at least one reach long, and a halved time step must not change the peak.
  5. Hand over the peaks, durations, directions and histories with the scenario names.

7 · Checklist

Surge analysis practice series
  1. Is your HAMMER run right? Time step, adjustment and run duration
  2. Validating a surge model with a field pump-trip test
  3. Sensitivity and uncertainty: bounding the result
  4. Pump data for a pump trip: inertia, specific speed and four-quadrant curves
  5. Demands, branches and dead ends in a transient model
  6. Reading the surge envelope against the pipe's real limits
  7. Transient forces on pipe supports and bends
  8. Booster stations in series
  9. Pump starts, controlled stops and drive ramps
  10. Filling, draining and restarting a transmission main
  11. Surge in wastewater force mains
  12. The surge study report: what to deliver and what a reviewer checks
The protection devices themselves are covered in the surge protection design series.

References & standards

  1. Wylie, E.B. & Streeter, V.L. Fluid Transients in Systems. Prentice Hall, 1993: unbalanced forces on pipe segments during transients and fluid-structure interaction.
  2. AWWA Manual M11 Steel Pipe: A Guide for Design and Installation, and AWWA Manual M41 Ductile-Iron Pipe and Fittings: thrust at bends and the design of restraint.
  3. Tijsseling, A.S. “Fluid-structure interaction in liquid-filled pipe systems: a review.” Journal of Fluids and Structures, 10(2), 1996: transient loads on pipe supports and their coupling with the pipe.
  4. Abokhatwa, M. Surge protection design series, abokhatwa.com, 2026: the 12 km DN800 reference main, its vessel and the verified MOC solver.
  5. Biggs, J.M. Introduction to Structural Dynamics. McGraw-Hill, 1964: dynamic load factors for rectangular pulses and ramp loads.
  6. Chopra, A.K. Dynamics of Structures, 4th ed. Pearson, 2012: response of single-degree-of-freedom systems to pulse loads.